Skip to content

Power cords for Cambodia

Beta

25 power cords for Cambodia: 230 V 50 Hz mains, no national approval required. Country-plug cords for OEM equipment (the local wall plug to IEC 60320), data center jumpers (IEC 60320) and industrial (IEC 60309) cords from our certification records, with the approvals each one carries.

These country pages are in beta. We are still completing the record of plugs, connectors and cords for each country, so more detail and updates are coming soon.

25 of these need no national approval in Cambodia.

Power in Cambodia

Mains supply
230 V · 50 Hz
Type A/C/G sockets coexist; datacenter market emerging; C13/C14 used at 230V.
Wall plug
Plug type not on our record yet — the IEC 60320 jumpers below fit any PDU or power-supply inlet.
Cord ratings
Under the IEC scheme, IEC 60320 C13 / C14 cords are rated 10 A 250 V and C19 / C20 cords 16 A 250 V; a wall-plug cord carries its plug's own rating.
Approvals
Cambodia names no mandatory product approval for a cord set, overseen by ISC (Institute of Standards of Cambodia) — Ministry of Industry, Science, Technology and Innovation (MISTI); standard export papers apply.
Regulator: ISC (Institute of Standards of Cambodia) — Ministry of Industry, Science, Technology and Innovation (MISTI)

Cord-set standard: Adoption of IEC 60320-1 / IEC 60227 / IEC 60884-1 as CS (Cambodian Standards) — voluntary. Cordage accepted: H05VV-F, SJT, RVV (Chinese GB cross-border). Labels in KM / English.

Industrial power cords for Cambodia

IEC 60309 pin-and-sleeve cords, 16–32 A — the international industrial connector, dual-rated for IEC and North American circuits.

Other power cords for Cambodia

Extension cords, splitters, hardwired whips and adapter cords approved for use in Cambodia.

Not on the record for Cambodia yet

  • Country plug cords — The wall plug used in Cambodia on one end and the IEC 60320 inlet on your equipment on the other — C13, C15, C5, C7 or C19. The cord an OEM ships in the box with equipment sold into Cambodia, and the one an office, lab or shop floor plugs straight into the wall; every cord here carries the approval Cambodia requires.
  • Data center cords — IEC 60320 jumpers — a C14 or C20 plug into the PDU, a C13, C15 or C19 connector into the server, switch or storage. For most countries these are our global cords: one part number carries the marks Cambodia requires, so a data center operator deploys the same cord in every region.

We list a cord here only when our certification record shows it is approved for use in Cambodia or needs no national approval there. Need one of these kinds for Cambodia? Ask us — we quote the cord and file the approval.

Questions about power cords for Cambodia

What is the mains voltage in Cambodia?

230 V at 50 Hz. Under the IEC scheme, IEC 60320 C13 / C14 cords are rated 10 A 250 V and C19 / C20 cords 16 A 250 V; a wall-plug cord carries its plug's own rating.

What approval does a power cord need in Cambodia?

Cambodia names no mandatory product approval for a cord set, overseen by ISC (Institute of Standards of Cambodia) — Ministry of Industry, Science, Technology and Innovation (MISTI); standard export papers apply. A cord marked "Approved for use in Cambodia" on this page carries that approval on our record; "No national approval required" means the record names none for that cord type.

Which cordage types are accepted in Cambodia?

H05VV-F, SJT and RVV (Chinese GB cross-border). Our international cords use harmonised H05VV-F / H05RN-F cordage; North American cords use SJT / SJTW.

Also in Asia-Pacific

"Approved for use in Cambodia" means the cord carries the approval Cambodia requires for its type. "No national approval required in Cambodia" means Cambodia names no national approval for a cord of that type. Need the certificate behind a cord, or a cord for a country not listed? Ask us.